1SBL297001R1311 ABB AF38-30-11-13 100-250V50/60HZ-DC Contactor

1SBL297001R1311 ABB AF38-30-11-13 100-250V50/60HZ-DC Contactor

Mfr#: ABB AF38-30-11-13
Prix Sur Demande
Délai de livraison : 13 jours Livraison estimée le vendredi 26 juin Commandez dans les --. Détails
En stock
Paiements 100% Sécurisés
VISA
Mastercard
PayPal
Orange
Money
Virement
Bancaire
Paiement
Par Chèque
Description
Extended Product Type: AF38-30-11-13
Product ID: 1SBL297001R1311
EAN: 3471523111639
Catalog Description: AF38-30-11-13 100-250V50/60HZ-DC Contactor
Long Description: The AF38-30-11-13 is a 3 pole - 690 V IEC or 600 UL contactor with pre-mounted auxiliary contacts and screw terminals, controlling motors up to 18.5 kW / 400 V AC (AC-3) or 25 hp / 480 V UL and switching power circuits up to 50 A (AC-1) or 50 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Product Net Width: 45 mm
Product Net Depth / Length: 111.5 mm
Product Net Height: 86 mm
Product Net Weight: 0.35 kg
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 1
Number of Auxiliary Contacts NC: 1
Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
Rated Operational Voltage: Auxiliary Circuit 690 V, Main Circuit 690 V
Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 50 Aacc. to IEC 60947-5-1, q = 40 °C 16 A
Rated Operational Current AC-1 (Ie): (690 V) 40 °C 50(690 V) 60 °C 42 A, (690 V) 70 °C 37
Rated Operational Current AC-3 (Ie): (415 V) 60 °C 38 A, (440 V) 60 °C 38 A, (500 V) 60 °C 33 A, (690 V) 60 °C 24 A, (380 / 400 V) 60 °C 38 A, (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Power AC-3 (Pe): (400 V) 18.5 kW, (415 V) 18.5 kW, (440 V) 22 kW, (500 V) 22 kW, (690 V) 22 kW, (380 / 400 V) 18.5 kW, (220 / 230 / 240 V) 11 kW
Rated Operational Current AC-15 (Ie): (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (400 / 440 V) 3 A
Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A, for 0.1 s 140 A, for 1 s 100 A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
Maximum Electrical Switching Frequency: (AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-2 / AC-4) 150 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie): (24 V) 6 A / 144 W, (48 V) 2.8 A / 134 W, (72 V) 1 A / 72 W, (110 V) 0.55 A / 60 W, (125 V) 0.55 A / 69 W, (220 V) 0.27 A / 60 W, (250 V) 0.27 A / 68 W, (400 V) 0.15 A / 60 W, (500 V) 0.13 A / 65 W, (600 V) 0.1 A / 60 W
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V, acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp): 6 kV
Maximum Mechanical Switching Frequency: 3600 cycles per hour
Rated Control Circuit Voltage (Uc): 50 Hz 100 ... 250 V50 Hz / 60 Hz 100 ... 250 V, 60 Hz 100 ... 250 VDC Operation 100 ... 250 V
Operate Time: Between Coil De-energization and NC Contact Closing 13 ... 98 ms, Between Coil De-energization and NO Contact Opening 11 ... 95 ms, Between Coil Energization and NC Contact Opening 38 ... 90 ms, Between Coil Energization and NO Contact Closing 40 ... 95 ms
Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 1.5 ... 10 mm², Flexible with Insulated Ferrule 1x 1.5 ... 10 mm², Flexible with Insulated Ferrule 2x 1.5 ... 4 mm², Rigid 1/2x 2.5 ... 10 mm²
Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length: Auxiliary Circuit 10 mm, Control Circuit 10 mm, Main Circuit 14 mm
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal Type: Screw Terminals